PM3

Soft X-ray dipole variable polarisation with PGM open port + scattering chamber

PM3 merges the developments of the former BESSY I SX700 III monochromator for elliptically polarized VUV radiation and of BESSY II collimated plane grating monochromators. This way it is possible to achieve circular polarization from a BESSY II dipole in the range 20 – 2000 eV with high photon flux, high energy resolution and high stability.

Röntgenoptisches Design der PM3

Röntgenoptisches Design der PM3


Beamline data
Segment H11
Location (Pillar) 13.2
Source D111 (Dipole)
Monochromator PM3
Energy range 20 - 1900 eV
Energy resolution 32000 at 64 eV
Flux 1e9 - 1e10
Polarisation • horizontal
• circular
Divergence horizontal 1.5 mrad
Divergence vertical 1 mrad
Focus size (hor. x vert.) 180 µm hor., vert. depends on exit slit
User endstation Possible
Distance Focus/last valve 350 mm
Height Focus/floor level 1432 mm
Beam availability 24h/d
Phone 0049 30 8062 13429
Applicable station(s)
GELEM-PEEM preparation: 300 – 3000 K
measurement: 300 K
ALICE II 10 - 475 K
SOLIAS 90 - 1000 K
User station
PM3 scattering 18 - 400 K
Lageplan

Lageplan

Elektronenausbeute auf Au für verschiedene Grade der Elliptizität

Elektronenausbeute auf Au für verschiedene Grade der Elliptizität

Energieauflösung @ 400 eV

Energieauflösung @ 400 eV

Rauschen der Röntgenintensität nah am "shot-noise"

Rauschen der Röntgenintensität nah am "shot-noise"


"PM3 merges the developments of the former BESSY I SX700 III monochromator for elliptically polarized VUV radiation and of BESSY II collimated plane grating monochromators. This way it is possible to achieve circular polarization from a BESSY II dipole in the range 20 – 2000 eV with high photon flux, high energy resolution and high stability." http://dx.doi.org/10.17815/jlsrf-2-73

For more details and current status contact the beamline scientist(s).