Imaging Ellipsometry for Process Control of Thin-Film Devices

Left: Thickness image of MXene-based capacitive comb-structure devices (light contrast) on a silicon wafer with 100 nm oxide (red). Right: Two magnifications highlighting film homogeneity at the microscale. With an average thickness of 5.4 nm, small variations across the microstructured device are visible according to the color scale.

Left: Thickness image of MXene-based capacitive comb-structure devices (light contrast) on a silicon wafer with 100 nm oxide (red). Right: Two magnifications highlighting film homogeneity at the microscale. With an average thickness of 5.4 nm, small variations across the microstructured device are visible according to the color scale. © Applied Physics Letters (2026)

Imaging ellipsometry maps of a MXene-based comb structure showing film thickness at two length scales (left, middle) as well as conductivity (right).

Imaging ellipsometry maps of a MXene-based comb structure showing film thickness at two length scales (left, middle) as well as conductivity (right). © Applied Physics Letters (2026)

A German–Israeli research team led by Dr. Andreas Furchner has demonstrated how imaging ellipsometry enables non-destructive characterisation and quality control of microstructured MXene thin films during device fabrication. The authors used two complementary ellipsometry approaches for precise, multi-scale access to key material properties. The work positions imaging ellipsometry as a powerful platform for monitoring thin-film uniformity, device integrity, and functionality throughout processing, including critical lithographic steps.  The study was published in Applied Physics Letters and selected as an Editor’s Pick.

MXenes are two-dimensional nanomaterials that can serve as building blocks for microscale electronic and photonic devices, often referred to as MXetronics. At Tel Aviv University, structured MXene-based thin films are being investigated as backside electrodes in next-generation photodetectors. Imaging ellipsometry turned out to be a crucial non-destructive technique for monitoring their properties throughout processing without damaging the device.

By analyzing changes in the polarization state of light reflected off the device, ellipsometry provides direct, quantitative access to thin-film characteristics such as thickness, composition, and charge-transport properties. The resulting optical contrast is highly sensitive to even subtle lateral variations across a sample. The method is not only imaging structures but also functionality, which makes ellipsometry valuable for device fabrication.

The authors pursued two optical approaches. Spectroscopic micro-ellipsometry (SME), available at The Hebrew University of Jerusalem, provides high-resolution single-spot measurements that enable rapid probing of samples. SME is well suited for targeted checks and high-throughput assessment during fabrication, giving a fast snapshot of what is happening at a precise point on the device.

Imaging spectroscopic ellipsometry (ISE), by contrast, provides spatially resolved imaging across full thin-film devices. At HZB, a Park Systems imaging ellipsometer is available for large-scale imaging, complemented by a unique focusing optic with lateral resolution down to 1 µm. This enables structural and functional film properties to be mapped across entire devices, effectively connecting millimeter to micrometer length scales in a single comprehensive measurement approach.

A particular strength of the method is its ability to monitor and visualize how local properties evolve during processing steps such as photoresist development. These changes can be tracked through their impact on the optical response, revealing spatial variations in charge-transport and structural properties without contacting the device. Local properties can thereby be correlated with overall device functionality, which is essential for  optimization and fabrication.

There is already keen interest in the method, both within HZB and from international research groups, which has led to ongoing collaborations. The highly versatile ellipsometer is suitable for analyzing a wide range of isotropic and anisotropic materials, including two-dimensional systems. The HZB team always welcomes interested researchers to get in touch for measurements or potential collaborations.

Andreas Furchner

  • Copy link

You might also be interested in

  • A New Era in Catalysis: ASCEND Launch in Berlin, €30 Million in Funding
    News
    12.06.2026
    A New Era in Catalysis: ASCEND Launch in Berlin, €30 Million in Funding
    On 11 June 2026, the Helmholtz-Zentrum Berlin (HZB) in Adlershof hosted the launch of ASCEND (Accelerated Solutions for Catalysis using Emerging Nanotechnology and Digital Innovation). The event took place in the presence of the Minister of Research, Dorothee Bär, President of the Helmholtz Association, Prof. Dr. Martin Keller, and President of the Max Planck Society, Prof. Dr. Patrick Cramer. Bringing together leading partners from industry and research, ASCEND is supported by BMFTR with €30 million in funding and officially started on 1 April 2026. The initiative aims to accelerate the discovery of next-generation catalysts and enable more sustainable chemical processes.
  • X-ray analysis reveals overpainted fascist symbols
    Science Highlight
    08.06.2026
    X-ray analysis reveals overpainted fascist symbols
    Erich Mercker was a successful painter during the Nazi era and in the years that followed. After 1945, he covered up Nazi symbols in at least one of his paintings. With an interdisciplinary team, physicist Dr Ioanna Mantouvalou reports on this study in the Nature Journal Heritage Science.
  • Magnon momentum microscopy: A new window into nanoscale spin-waves
    Science Highlight
    08.06.2026
    Magnon momentum microscopy: A new window into nanoscale spin-waves
    An international team lead by the Max Born Institute has developed a new type of momentum microscopy to image magnons — the quanta of collectively excited spins — directly in two-dimensional reciprocal space using soft X-rays. Measurements have taken place at BESSY II and PETRA III, first author ist the HZB physicist Steffen Wittrock. Owing to its remarkable sensitivity, simplicity, and access to nanometer-scale wavelengths, this novel technique establishes a powerful and versatile platform for exploring nonlinear magnon interactions, which are promising for future computing schemes.