• Isaev, I.I.; Boonpornprasert, P.; Good, J.D.; Groß, M.; Hakobyan, L.; Khojoyan, M.; Kourkafas, G.; Köhler, W.; Krasilnikov, M.; Malyutin, D.; Marchetti, B.; Martin, R.; Nozdrin, M.A.; Oppelt, A.; Otevrel, M.; Pathak, G.; Petrosyan, B.; Shapovalov, A.; Stephan, F.; Vashchenko, G.; Wenndorff, R.W.; Jachmann, L.; Asova, G.; Richter, D.; Rimjaem, S.: Conditioning Status of the First XFEL Gun at PITZ. In: FEL2013: Proceedings of the 35th International Free-Electron Laser Conference, Manhattan, NY, USA, August 26-30 2013Proceedings of FEL2013, New York, NY, USA, 2013. - ISBN 978-3-95450-126-7, p. 282-286
    http://accelconf.web.cern.ch/AccelConf/FEL2013/papers/tupso30.pdf

Open Access Version

Abstract:
The paper describes the recent results of conditioning and dark current measurements for the photocathode RF gun at the photoinjector test facility at DESY, Zeuthen site (PITZ). The aim of PITZ is to develop and operate an optimized photo injector for free electron lasers and linear accelerators which require high quality beams. In order to get high gradients in the RF gun extensive conditioning is required. A data analysis of the conditioning process is based on data saved by a Data Acquisition system (DAQ). Conditioning results of the first gun cavity for the XFEL is presented. The events which occurred during the conditioning are briefly described.