Beam diagnostics for future laser wakefield accelerators

Information on beam quality can be extracted via the interference patterns at different focal lengths and photon intensities.</p> <p>

Information on beam quality can be extracted via the interference patterns at different focal lengths and photon intensities.

© www.nature.com/articles/s42005-021-00717-x

The laser wakefield acceleration (simulation): The laser pulse (not shown) is moving to the right and is so intense that it expels all the plasma electrons from its path and creates a bubble-like feature in the plasma, which contains positively charged ions and hence has strong electric fields that pull electrons into the bubble and accelerate them as they ride along with the laser pulse.

The laser wakefield acceleration (simulation): The laser pulse (not shown) is moving to the right and is so intense that it expels all the plasma electrons from its path and creates a bubble-like feature in the plasma, which contains positively charged ions and hence has strong electric fields that pull electrons into the bubble and accelerate them as they ride along with the laser pulse. © Joshua Ludwig, cc 4.0 wikimedia.org/wiki/File:Frame_000000100_extra_terrible_resolution.png

For decades, particle accelerators have been getting bigger and bigger. In the meantime, ring accelerators with circumferences of many kilometres have reached a practical limit. Linear accelerators in the GHz range also require very long construction lengths. For some years now, however, an alternative is explored: "tabletop particle accelerators" based on the laser excitation of charge waves in plasmas (laser wakefield). Such compact particle accelerators would be particularly interesting for future accelerator-driven light sources, but are also being investigated for high-energy physics. A team from Helmholtz-Zentrum Berlin (HZB) and the Physikalisch-Technische Bundesanstalt (PTB) has developed a method to precisely measure the cross-section of electron bunches accelerated in this way.  This brings applications of these new accelerator technologies for medicine and research closer.

The principle of laser wakefield accelerators: A high-power laser excites a charge wave in a plasma, which propagates at the speed of the laser pulse and pulls electrons behind it in its "wake", thus accelerating them. Electron energies in the GeV range have been achievable with this technique for some time. However, the electron bunches produced in this way have so far been too small and too poorly focused to use the synchrotron radiation they emit, an intense, coherent light that is used for research in many different disciplines.

For the further development of the technology, a method is therefore needed to precisely measure and control the cross-section and quality of the electron bunches individually. PTB's storage ring, the Metrology Light Source (MLS), allows the generation of small electron bunches in flexible research operation, which are very similar to those of laser wakefield accelerators, but whose properties can be set and varied very reproducibly and precisely. A team at HZB and PTB has now developed a method to measure the lateral expansion of the electron beam of a laser plasma accelerator with a resolution in the micrometre range.

"To do this, we use a technique that is successfully employed at the Bessy II storage ring," explains Thorsten Kamps, co-author of the study. First author Ji-Gwang Hwang had the idea of using the coherent radiation of electron pulses in the visible range via the phenomenon of interference (double slit) and determining the beam cross-section as a deviation from a perfect point source. With the help of a highly sensitive camera and complex algorithms, the team succeeded in measuring the lateral beam size in the range of a few micrometres. Katharina Albrecht carried out the measurements as part of her bachelor's thesis in physics. "We worked very closely with our colleagues from the (MLS) at PTB for this project," Kamps emphasises. "There, it is possible to imitate the electron beam from a plasma accelerator on a beamline and thus test the method under realistic conditions," says Kamps.

Note: The work described here takes place within the framework of the ATHENA project - "Accelerator Technology Helmholtz Infrastructure".  This is a new research and development platform of the Helmholtz Association for accelerator technologies. Based on innovative plasma-based particle accelerators and state-of-the-art laser technology, two lighthouse projects are to be established: an electron accelerator facility at DESY in Hamburg and a hadron accelerator facility in Dresden. At both facilities, different fields of application are to be developed, ranging from a compact free-electron laser to novel medical applications and new applications in nuclear and particle physics.

arö

  • Copy link

You might also be interested in

  • Superconducting TES array X-ray spectrometer goes into operation at BESSY II
    Science Highlight
    15.06.2026
    Superconducting TES array X-ray spectrometer goes into operation at BESSY II
    Europe's first and only TES-spectrometer at a synchrotron source is now in operation at BESSY II, developed within a collaboration between the HZB, the MPI-CEC (Mühlheim-an-der-Ruhr, Germany) and the NIST (Boulder CO, USA). The photon detection efficiency of the new instrument exceeds that of wavelength-dispersive X-ray emission spectrometers by a factor of 100 to 1000.  It will be used to investigate the electronic properties of atomically thin layers, nanostructures and highly diluted atomic and molecular samples. The team is looking forward to receiving exciting research proposals from the user community.
  • A New Era in Catalysis: ASCEND Launch in Berlin, €30 Million in Funding
    News
    12.06.2026
    A New Era in Catalysis: ASCEND Launch in Berlin, €30 Million in Funding
    On 11 June 2026, the Helmholtz-Zentrum Berlin (HZB) in Adlershof hosted the launch of ASCEND (Accelerated Solutions for Catalysis using Emerging Nanotechnology and Digital Innovation). The event took place in the presence of the Minister of Research, Dorothee Bär, President of the Helmholtz Association, Prof. Dr. Martin Keller, and President of the Max Planck Society, Prof. Dr. Patrick Cramer. Bringing together leading partners from industry and research, ASCEND is supported by BMFTR with €30 million in funding and officially started on 1 April 2026. The initiative aims to accelerate the discovery of next-generation catalysts and enable more sustainable chemical processes.
  • Magnon momentum microscopy: A new window into nanoscale spin-waves
    Science Highlight
    08.06.2026
    Magnon momentum microscopy: A new window into nanoscale spin-waves
    An international team lead by the Max Born Institute has developed a new type of momentum microscopy to image magnons — the quanta of collectively excited spins — directly in two-dimensional reciprocal space using soft X-rays. Measurements have taken place at BESSY II and PETRA III, first author ist the HZB physicist Steffen Wittrock. Owing to its remarkable sensitivity, simplicity, and access to nanometer-scale wavelengths, this novel technique establishes a powerful and versatile platform for exploring nonlinear magnon interactions, which are promising for future computing schemes.