New monochromator optics for tender X-rays

Schematic drawing of the novel monochromator concept at the U41-PGM1 beamline at BESSY-II based on a multilayer coated blazed plane grating and mirror to improve the photon flux in the tender X-ray photon energy range (1.5 – 5.0 keV). The inset shows a TEM image of the cross-section of the Cr/C multilayer blazed grating structures. For better visualization of the grating period, the image was horizontally compressed 10 fold.

Schematic drawing of the novel monochromator concept at the U41-PGM1 beamline at BESSY-II based on a multilayer coated blazed plane grating and mirror to improve the photon flux in the tender X-ray photon energy range (1.5 – 5.0 keV). The inset shows a TEM image of the cross-section of the Cr/C multilayer blazed grating structures. For better visualization of the grating period, the image was horizontally compressed 10 fold. © HZB / Small Methods 2022

X-ray microscopy images of a 400 nm thick lamella cut out of a modern microchip device. The individual images were taken from a microspectrocopic energy series at the Si-K absorption edge. The NEXAFS spectra were extracted from the acquired energy series for SiCN and OSG materials. The corresponding energy peaks are related to the dominating Si-C bonds for SiCN and the dominating Si-O bonds for OSG dielectrics.</p> <p>&nbsp;

X-ray microscopy images of a 400 nm thick lamella cut out of a modern microchip device. The individual images were taken from a microspectrocopic energy series at the Si-K absorption edge. The NEXAFS spectra were extracted from the acquired energy series for SiCN and OSG materials. The corresponding energy peaks are related to the dominating Si-C bonds for SiCN and the dominating Si-O bonds for OSG dielectrics.

  © HZB / Small Methods 2022

Until now, it has been extremely tedious to perform measurements with high sensitivity and high spatial resolution using X-ray light in the tender energy range of 1.5 - 5.0 keV. Yet this X-ray light is ideal for investigating energy materials such as batteries or catalysts, but also biological systems. A team from HZB has now solved this problem: The newly developed monochromator optics increase the photon flux in the tender energy range by a factor of 100 and thus enable highly precise measurements of nanostructured systems. The method was successfully tested for the first time on catalytically active nanoparticles and microchips.

 

A climate-neutral energy supply requires a wide variety of materials for energy conversion processes, for example catalytically active materials and new electrodes for batteries. Many of these materials have nanostructures that increase their functionality. When investigating these samples, spectroscopic measurements to detect the chemical properties are ideally combined with X-ray imaging with high spatial resolution at the nanoscale. However, since key elements in these materials, such as molybdenum, silicon or sulphur, react predominantly to X-rays in the so-called tender photon energy range, there has been a major problem until now.

This is because in this "tender" energy range between soft and hard X-rays, conventional X-ray optics from plane grating or crystal monochromators deliver only very low efficiencies. A team from HZB has now solved this problem: "We have developed novel monochromator optics. These optics are based on an adapted, multilayer-coated sawtooth grating with a plane mirror," says Frank Siewert from the HZB Optics and Beamlines Department. The new monochromator concept increases the photon flux in the tender X-ray range by a factor of 100 and thus enables highly sensitive spectromicroscopic measurements with high resolutions for the first time. "Within a short time we were able to collect data from NEXAFS spectromicroscopy on the nanoscale. We have demonstrated this on catalytically active nanoparticles and modern microchip structures," says Stephan Werner, first author of the publication. "The new development now enables experiments that would otherwise have required months of data collection," Werner emphasises.

"This monochromator will become the method of choice for imaging in this X-ray energy range, not only at synchrotrons worldwide, but also at free-electron lasers and laboratory sources," says Gerd Schneider, who heads the X-ray Microscopy Department at HZB. He expects enormous effects on many areas of materials research: Studies in the tender X-ray range could significantly advance the development of energy materials and thus contribute to climate-neutral solutions for electricity and energy supply.

arö

  • Copy link

You might also be interested in

  • Protein crystallography at BESSY II: faster, better and more and more automatic
    Interview
    04.03.2026
    Protein crystallography at BESSY II: faster, better and more and more automatic
    Many diseases are linked to malfunctions of proteins in the organism. The three-dimensional architecture of these molecules is often highly complex, but it can provide valuable insights into biological processes and the development of drugs. X-ray diffraction at the MX beamlines of BESSY II can be used to decipher the 3D structure of proteins. To date, more than 5000 structures have been solved at the three MX beamlines. Here, we present a review and an outlook with  Manfred Weiss, head of the research group for macromolecular crystallography. 
  • Humboldt-Fellow at HZB-Institute for Solar Fuels: Alexander R. Uhl
    News
    02.03.2026
    Humboldt-Fellow at HZB-Institute for Solar Fuels: Alexander R. Uhl
    Alexander R. Uhl, UBC Okanagan School of Engineering in Kelowna, Canada, aims to develop with Roel van de Krol from the HZB Institute for Solar Fuels an efficient and inexpensive photoelectrolyser for producing hydrogen using sunlight. His stay is being funded by the Alexander von Humboldt Foundation.
  • 5000th protein structure at BESSY II: Starting point for a COVID drug
    Science Highlight
    26.02.2026
    5000th protein structure at BESSY II: Starting point for a COVID drug
    Many proteins have a complex architecture that enables biological functions. Molecules can bind to specific sites on a protein and alter its function. A team at HZB has now investigated the Nsp1 protein, which plays a role in infection with the SARS-CoV-2 virus. They analysed protein crystals, previously mixed with molecules from a fragment library, and discovered a total of 21 candidates as starting points for drug development. At the same time, they also decoded the 5000th structure at BESSY II.