“Multi-spectra glasses” for scanning electron microscopy

Photo of the new WDS instrument that is connected to a scanning electron microscope (Zeiss EVO 40) by means of a standard housing and mounting flange.

Photo of the new WDS instrument that is connected to a scanning electron microscope (Zeiss EVO 40) by means of a standard housing and mounting flange.

Measured spectra of Be-K (above) and Ga-L (below) fluorescence lines.

Measured spectra of Be-K (above) and Ga-L (below) fluorescence lines.

Reflection zone plates produced by HZB enable lighter elements in material samples to be precisely detected using scanning electron microscopy (SEM) by providing high resolution in the range of 50-1120 eV.

The scanning electron microscope is not only used for precisely surveying the surface topology of samples, but also for determining their chemical compositions. This is done by exciting the atoms to fluoresce under irradiation by an electron beam while scanning the sample. This secondary emission provides information about the location and type of element, insofar as the analysis is sufficiently precise. However, the lighter elements of the periodic table such as lithium, beryllium, boron, carbon, and nitrogen emit secondary fluorescence in an energy range that cannot be sufficiently well resolved by energy dispersive spectrometers (EDS).

A solution to this problem has now been developed at HZB. Prof. Alexei Erko, head of HZB’s Institute for Nanometre Optics and Technology, has previously designed and patented innovative optics using what is known as reflection zone plates. They are employed in synchrotron sources like BESSY II for analysing soft X-ray radiation. This optics, consisting of several thousand concentric or elliptical structures, do not refract the radiation the way a glass lens does, but instead diffract them so that interference occurs.

“Our colleagues from the company IfG Institute for Scientific Instruments had asked me if reflection zone plate optics could also be used in an electron microscope to increase the resolution in the low-energy region. Based on this idea a research project at the non-profit Institut für angewandte Photonik e. V. and at the company IfG GmbH, a following product development project was executed resulting in a functional prototype of a specialised wavelength dispersive spectrometer (WDS). Using this instrument you can very precisely detect the light elements such as lithium, boron, beryllium, carbon and oxygen with an electron microscope”, explains Erko.

The spectrometer consists of an array of 17 reflection zone plates covering the energy range of 50-1120 eV. To achieve even higher resolution, the scientists produced optics using 200 reflection zone plates to provide nearly continuous spectral measurements in the energy range of 100-1000 eV.

“High resolution in this energy range is important for detecting lighter elements of the periodic table. That is particularly important for research on energy-related materials like solar cells, batteries, and solar fuels, as well as catalysts. But it could also be useful in research on magnetic materials and in life sciences. We are very excited about what this new tool can be used for”, says Erko.

Original publication: 14 July 2014 | Vol. 22, No. 14 | DOI:10.1364/OE.22.016897 | OPTICS EXPRESS 16897

arö

  • Copy link

You might also be interested in

  • Imaging Ellipsometry for Process Control of Thin-Film Devices
    Science Highlight
    22.05.2026
    Imaging Ellipsometry for Process Control of Thin-Film Devices
    A German–Israeli research team led by Dr. Andreas Furchner has demonstrated how imaging ellipsometry enables non-destructive characterisation and quality control of microstructured MXene thin films during device fabrication. The authors used two complementary ellipsometry approaches for precise, multi-scale access to key material properties. The work positions imaging ellipsometry as a powerful platform for monitoring thin-film uniformity, device integrity, and functionality throughout processing, including critical lithographic steps.  The study was published in Applied Physics Letters and selected as an Editor’s Pick.
  • BESSY II: How intrinsic oxygen shortens the lifespan of solid-state batteries
    Science Highlight
    08.05.2026
    BESSY II: How intrinsic oxygen shortens the lifespan of solid-state batteries
    Although solid-state batteries (SSBs) demonstrate high performance and are intrinsically safe, their capacity currently declines rapidly. A team from the TU Wien, Humboldt-University Berlin and HZB has now analysed a TiS₂|Li₃YCl₆ solid-state half-cell in operando at BESSY II using a special sample environment that allows for non-destructive investigation under real operating conditions. Data obtained by combination of soft and hard X-ray photoelectron spectroscopy (XPS and HAXPES) revealed a new degradation mechanism that had not previously been identified in solid-state batteries. They have gained some surprising insights, particularly regarding the harmful role played by intrinsic oxygen. This study provides valuable information for improving design and handling of such batteries.
  • Spintronics at BESSY II: Real-time analysis of magnetic bilayer systems
    Science Highlight
    29.04.2026
    Spintronics at BESSY II: Real-time analysis of magnetic bilayer systems
    Spintronic devices enable data processing with significantly lower energy consumption. They are based on the interaction between ferromagnetic and antiferromagnetic layers. Now, a team from Freie Universität Berlin, HZB and Uppsala University has succeeded in tracking, for each layer separately, how the magnetic order changes after a short laser pulse has excited the system. They were also able to identify the main cause of the loss of antiferromagnetic order in the oxide layer: the excitation is transported from the hot electrons in the ferromagnetic metal to the spins in the antiferromagnet.