New sample holder for protein crystallography

Up to three indivudal drops may be placed onto the sample holder.

Up to three indivudal drops may be placed onto the sample holder. © HZB

24 sample holders are grouped.

24 sample holders are grouped. © HZB

After their formation the tiny crystals are prepared for x-ray analysis - without touching them. They stay onto the same sample holder.

After their formation the tiny crystals are prepared for x-ray analysis - without touching them. They stay onto the same sample holder. © HZB

An HZB research team has developed a novel sample holder that considerably facilitates the preparation of protein crystals for structural analysis. A short video by the team shows how proteins in solution can be crystallised directly onto the new sample holders themselves, then analysed using the MX beamlines at BESSY II. A patent has already been granted and a manufacturer found.

Proteins are huge molecules that often have complex three-dimensional structure and morphology that can include side chains, folds, and twists. This three-dimensional shape is often the determining factor of their function in organisms. It is therefore important to understand the structure of proteins both for fundamental research in biology and for the development of new drugs. To accomplish this, proteins are first precipitated from solution as tiny crystals, then analysed using facilities such as the MX beamlines at BESSY II in order to generate a computer image of the macromolecular structure from the data.

Up to now, protein crystals have first been grown and then transferred onto a sample holder for structural analysis. However, this transfer entailed a risk of destroying the often extremely fragile crystals.

This risk is no longer necessary thanks to the new sample holder developed by Dr. Manfred Weiss and Dr. Christian Feiler from the MX team together with Dr. Dirk Wallacher from the BESSY II sample environment group. Instead, the protein solution is applied directly onto the sample holder and crystallised in place, eliminating the need to transfer the delicate protein crystals to a different sample holder for analysis. “The new sample holder saves work steps and reduces the risk of damaging the sensitive protein crystals“, explains Feiler. “We have a short video clip that shows step-by-step how these sample holders facilitate protein crystallography – you have to see this!” exclaims Weiss, head of the MX-Beamline.

In practice, a large number of samples are always measured at once, so 24 sample holders are grouped together onto one sample plate. The new sample holder is patented in Germany and registered for an international patent. Jena Bioscience has acquired a licence and is already marketing the new development worldwide.

Published in  J. Vis. Exp. (2019): An All-in-one Sample Holder for Macromolecular X-ray Crystallography with Minimal Background Scattering. Christian G. Feiler, Dirk Wallacher, Manfred S. Weiss

doi:10.3791/59722

Video and publication

S. Furtak/red.

  • Copy link

You might also be interested in

  • BESSY II: How intrinsic oxygen shortens the lifespan of solid-state batteries
    Science Highlight
    08.05.2026
    BESSY II: How intrinsic oxygen shortens the lifespan of solid-state batteries
    Although solid-state batteries (SSBs) demonstrate high performance and are intrinsically safe, their capacity currently declines rapidly. A team from the TU Wien, Humboldt-University Berlin and HZB has now analysed a TiS₂|Li₃YCl₆ solid-state half-cell in operando at BESSY II using a special sample environment that allows for non-destructive investigation under real operating conditions. Data obtained by combination of soft and hard X-ray photoelectron spectroscopy (XPS and HAXPES) revealed a new degradation mechanism that had not previously been identified in solid-state batteries. They have gained some surprising insights, particularly regarding the harmful role played by intrinsic oxygen. This study provides valuable information for improving design and handling of such batteries.
  • Spintronics at BESSY II: Real-time analysis of magnetic bilayer systems
    Science Highlight
    29.04.2026
    Spintronics at BESSY II: Real-time analysis of magnetic bilayer systems
    Spintronic devices enable data processing with significantly lower energy consumption. They are based on the interaction between ferromagnetic and antiferromagnetic layers. Now, a team from Freie Universität Berlin, HZB and Uppsala University has succeeded in tracking, for each layer separately, how the magnetic order changes after a short laser pulse has excited the system. They were also able to identify the main cause of the loss of antiferromagnetic order in the oxide layer: the excitation is transported from the hot electrons in the ferromagnetic metal to the spins in the antiferromagnet.
  • Environmental Chemistry at BESSY II: Radicals in waterways
    Science Highlight
    09.04.2026
    Environmental Chemistry at BESSY II: Radicals in waterways
    How do radicals form in aqueous solutions when exposed to UV light? This question is important for health research and environmental protection, for example with regard to the overfertilisation of water bodies by intensive agriculture. A team at BESSY II has now developed a new method of investigating hydroxyl radicals in solution. By using a clever trick, the scientists gained surprising insights into the reaction pathway.