More information from microscopy images by computing power

The first meeting of the Helmholtz Ptychography 4.0 Incubator Project took place at the Helmholtz-Zentrum Berlin (HZB) on November 27, 2019. Seven Helmholtz Centres intend to jointly develop advanced image data analysis and processing methods in order to extract more information from electron and X-ray microscopy images. In particular, the approach will be to use “virtual lenses” to correct imaging errors and thus considerably increase the resolution of images.

Ptychography 4.0 is one of the pilot projects of the Helmholtz Association’s Incubator programme in the field of information and data sciences and is being funded with almost 1.7 million euro by the Initiative and Networking Fund of the President of the Helmholtz Association. The individual participating Helmholtz Centres will be contributing matching funds.

“Ptychography 4.0 is a project in which we are working towards considerably increasing the resolution of electron microscopy as well as X-ray microscopy by correcting imaging errors mathematically”, explains Dr. Markus Wollgarten, head of the CoreLab for Correlative Spectroscopy and Microscopy at the HZB. It should be possible, for example, to display fine surface features of bacteria and viruses with extreme sharpness and to image new materials such as graphene with atomic-level precision without having to resort to expensive corrector optics.

In conventional microscopy, an electron beam or light beam (photons) is sent through the sample. A detector behind it measures the transmitted intensity to obtain an image of the sample. However, valuable information about sample-dependent phase change of the radiation is lost. Ptychography 4.0 will take this information into account mathematically and incorporate it in the analysis. Although this requires data rates in the gigabyte/second range, it allows the sample structure to be reconstructed mathematically with great accuracy. Therefore, many kinds of imaging errors caused by the microscope itself will become practically irrelevant.

The participating partners now want to further develop this approach and optimise the method for routine usage with different types of radiation, such as X-rays, electrons, and XUV light. In particular, image reconstruction is to be accelerated enough that real-time images become feasible.

“As a result of Ptychography 4.0, we will be able to avoid these limiting imaging errors, so that we can dispense with very cost-intensive physical corrector optics. Considerably more research institutes will be able to afford state-of-the-art high-resolution microscopy in the future”, emphasizes Wollgarten.

Participating Helmholtz Centres:
Deutsches Elektronen-Synchrotron (DESY)
Forschungszentrum Jülich (FZJ)
Helmholtz Institute Jena (GSI/HI-Jena)
Helmholtz Zentrum München (German Research Centre for Environmental Health/HMGU)
Helmholtz-Zentrum Berlin (HZB)
Helmholtz-Zentrum Dresden-Rossendorf (HZDR)
Helmholtz Centre for Infection Research (HZI)

Project Coordination:
Adj. Prof. Wolfgang zu Castell
Helmholtz Zentrum München (German Research Centre for Environmental Health/HMGU)
castell@helmholtz-muenchen.de
Prof. Christian Schroer
Deutsches Elektronen-Synchrotron (DESY)
christian.schroer@desy.de

Dr. Gerd Schneider (X-ray microscopy) as well as Ants Finke (IT Department) at HZB are also involved.

arö

  • Copy link

You might also be interested in

  • X-ray analysis reveals overpainted fascist symbols
    Science Highlight
    08.06.2026
    X-ray analysis reveals overpainted fascist symbols
    Erich Mercker was a successful painter during the Nazi era and in the years that followed. After 1945, he covered up Nazi symbols in at least one of his paintings. With an interdisciplinary team, physicist Dr Ioanna Mantouvalou reports on this study in the Nature Journal Heritage Science.
  • Magnon momentum microscopy: A new window into nanoscale spin-waves
    Science Highlight
    08.06.2026
    Magnon momentum microscopy: A new window into nanoscale spin-waves
    An international team lead by the Max Born Institute has developed a new type of momentum microscopy to image magnons — the quanta of collectively excited spins — directly in two-dimensional reciprocal space using soft X-rays. Measurements have taken place at BESSY II and PETRA III, first author ist the HZB physicist Steffen Wittrock. Owing to its remarkable sensitivity, simplicity, and access to nanometer-scale wavelengths, this novel technique establishes a powerful and versatile platform for exploring nonlinear magnon interactions, which are promising for future computing schemes.
  • Magnetic field during catalyst synthesis triples ammonia yield
    Science Highlight
    01.06.2026
    Magnetic field during catalyst synthesis triples ammonia yield
    Applying an external magnetic field during the synthesis of CoFe₂O₄ electrocatalysts triples the ammonia yield during electrocatalytic conversion. The magnetic field alters the surface states of the spinel oxide thin films, making catalytically active sites more accessible. In the journal 'Advanced Functional Materials', a team led by Marcel Risch at HZB and Sanjay Mathur at University of Cologne demonstrates a scalable strategy for developing next-generation electrocatalysts for efficient and sustainable chemical production.