• Ozkan, Cigdem; Freund, Wolfgang; Rehanek, Jens; Buck, Jens; Zizak, Ivo; Gruenert, Jan; Schaefers, Franz; Erko, Alexei; Molodtsov, Sergeui: Initial Evaluation of the European XFEL Undulator Commissioning Spectrometer with a Single Channel-Cut Crystal. In: Stefan P. Moeller ... [Ed.] : X-ray free-electron lasers: beam diagnostics, beamline instrumentation, and applications : 13 - 16 August 2012, San Diego, California, United StatesSPIE: Bellingham, Wash. , 2012 (Proceedings of SPIE ; 8504). - ISBN 978-0-8194-9221-0, p. 8504 0X

10.1117/12.929755

Abstract:
At the European X-ray Free Electron Laser facility one- or two-Si(111) channel (cut) crystal X-ray monochromator (K-monochromator) are planned for photon beam based alignment: gap tuning of the undulator segments and phase tuning of the phase shifters during commissioning and maintenance of the undulators. A prototype device has been built using a single channel-cut crystal and was characterized at PETRAIII synchrotron (at P01, which is the only beamline with two undulator segments) by applying different undulator adjustment methods, intended for the European XFEL, that use imaging and intensity detection. This paper presents the setup and the first results from the experimental qualification of the K-monochromator prototype.