KMC-1
KMC-1
The KMC-1 is a tender x-ray double crystal monochromator beamline for the energy range between 2 and 12 keV. The beamline and experiment are under UHV-condition.
Optical layout of the KMC-1 beamline
Beamline data | |
---|---|
Segment | H01 |
Location (Pillar) | 3.1 |
Source | D11 (Dipole) |
Monochromator | KMC-1; Crystal pairs available: Si(111), Si(311), Si(422). |
Energy range | Si(111):2 - 12 keV; Si(311): 4 - 12 keV; Si(422): 6 - 12 keV |
Energy resolution | 1000 at 4 keV |
Flux | 1e11 at 4 keV |
Polarisation | horizontal |
Divergence horizontal | 3 mrad |
Divergence vertical | 0.2 mrad |
Focus size (hor. x vert.) | 0.4 x 0.6 mm |
User endstation | possible |
Distance Focus/last valve | 670 mm |
Height Focus/floor level | 1728 mm |
Beam availability | 24h/d |
Phone | +49 30 8062 14838 |
Applicable station(s) | |
HIKE | tested: 71 K to 1023 K |
Small Reflectometer | room temperature |
Typical experiments are:
- HIKE (High Kinetic Energy Photoelectron Spectroscopy) or HAXPES (Hard X-Ray Photoelectron Spectroscopy)
- EXAFS, NEXAFS, XANES
- Diffractometry, Reflectometry