UE46_MAXYMUS
UE46_MAXYMUS is a undulator beamline optimized for producing high coherent flux of soft x-rays with selectable polarization using its APPLE2 type undulator, which is followed by a plane grating monochromator using a 600 lines/mm blazed grating. To create fully coherent light a pair of exit slits creates a virtual source of selectable size in the exit slit plane, on which it is centered using an automated beam position feedback system. The only endstation at this beamline is the MAXYMUS STXM.
Station data | |
---|---|
Temperature range |
|
Pressure range |
|
More details | MAXYMUS |
Beamline data | |
Segment | L10 |
Location (Pillar) | 12.1 |
Source | elliptical undulator UE46 |
Monochromator |
|
Energy range | 200 - 1900 eV |
Energy resolution | > 5 000 |
Flux | 200 eV - 1000 eV: ~ 1013 Ph/sec/100mA |
Polarisation | Horizontal, Vertical, Circular positive, Circular negative |
Divergence horizontal | n.a. mrad |
Divergence vertical | n.a. mrad |
Focus size (hor. x vert.) |
|
User endstation | not possible |
Distance Focus/last valve | n.a. mm |
Height Focus/floor level | 1400 mm |
Beam availability | 12h/d |
Phone | +49 30 8062 14762 |
For more details and current status contact the beamline scientist(s).
Publications:
The X-ray microscopy beamline UE46-PGM2 at BESSY
10th International Conference on Synchrotron Radiation Instrumentation, 323-326 (Hrsg. Garrett, R.; Gentle, I.; Nugent, K.; Wilkins, S.). 10th International Conference on Synchrotron Radiation Instrumentation (SRI 2009), Melbourne, Australia, 2009-09-27 - 2009-09-27. American Institute of Physics, Melville, NY (2010)